Kaspersky SD-WAN
- Kaspersky SD-WAN Help
- About Kaspersky SD-WAN
- Architecture of the solution
- Deploying Kaspersky SD-WAN
- Redundancy of solution components
- About the installation archive
- About the attended, unattended, and partially attended action modes
- Preparing the administrator device
- Managing passwords
- Preparing the configuration file
- Replacing the graphics of the orchestrator web interface
- Replacement of a failed controller node
- Upgrading Kaspersky SD-WAN
- Removing Kaspersky SD-WAN
- Logging in and out of the orchestrator web interface
- Licensing of Kaspersky SD-WAN
- User interface of the solution
- Navigating to the orchestrator API
- Managing the Kaspersky SD-WAN infrastructure
- Managing domains
- Managing data centers
- Managing management subnets
- Managing controllers
- Managing a VIM
- Managing users and their access permissions
- Multitenancy
- Managing CPE devices
- About the interaction of the CPE device and the orchestrator
- About the interaction of the CPE device and the controller
- Default credentials of KESR CPE devices
- Scenario: Automatic registration (ZTP) of a CPE device
- Scenario: Deployment on the VMware virtualization platform and automatic registration (ZTP) of a vCPE device
- Scenario: Re-registering a CPE device
- Managing CPE templates
- Managing CPE devices
- Adding a CPE device
- Generating an URL with basic CPE device settings
- Manually registering a CPE device
- Unregistering a CPE device
- Specifying the address of a CPE device
- Enabling and disabling a CPE device
- Restarting a CPE device
- Shutting down a CPE device
- Connecting to the CPE device console
- Viewing the password of a CPE device
- Exporting orchestrator and controller connection settings and SD-WAN interfaces from a CPE device
- Exporting network interfaces from a CPE device
- Changing the DPID of a CPE device
- Deleting CPE devices
- Two-factor authentication of a CPE device
- Managing certificates
- Automatically deleting and disabling CPE devices
- Grouping CPE devices using tags
- Configuring logs on CPE devices
- Specifying NTP servers on CPE devices
- Managing modems
- Updating firmware
- Manually updating firmware on a CPE device
- Uploading firmware to the orchestrator web interface
- Scheduling firmware updates on selected CPE devices
- Scheduling firmware updates on CPE devices with specific tags
- Restoring firmware of a KESR-M1 CPE device
- Restoring firmware of a KESR-M2-5 CPE device
- Correspondence of CPE device models with firmware versions
- Deleting firmware
- Additional configuration of CPE devices using scripts
- Managing network interfaces
- Creating network interfaces
- Creating a network interface with automatic assignment of an IP address via DHCP
- Creating a network interface with a static IPv4 address
- Creating a network interface with a static IPv6 address
- Creating a network interface for connecting to an LTE network
- Creating a network interface for connecting to a PPPoE server
- Creating a network interface without an IP address
- Editing a network interface
- Disabling or enabling a network interface
- Canceling the application of network interface settings to a CPE device
- Deleting a network interface
- Creating network interfaces
- Configuring the connection of a CPE device to the orchestrator and controller
- Managing SD-WAN interfaces
- About sending information about SD-WAN interfaces of the WAN type to the controller
- Package fragmentation
- Traffic queues on SD-WAN interfaces
- Creating an SD-WAN interface of the WAN type
- Editing an SD-WAN interface
- Disabling or enabling an SD-WAN interface
- Deleting an SD-WAN interface of the WAN type
- Managing service interfaces
- Managing OpenFlow port groups
- Configuring a UNI for connecting CPE devices to network services
- Adding a static route
- Filtering routes and traffic packets
- Route exchange over BGP
- Route exchange over OSPF
- Using BFD to detect routing failures
- Ensuring high availability with VRRP
- Transmission of multicast traffic using PIM and IGMP protocols
- Managing virtual routing and forwarding (VRF) tables
- Monitoring traffic packet information using the NetFlow protocol
- Diagnosing a CPE device
- Running scheduled tasks on CPE devices
- IP address and subnet ranges for CPE devices
- Managing the firewall
- Managing network services and virtualization of network functions
- Managing network service templates
- Managing network services
- Scenario: Deploying a virtual network function
- Scenario: Deploying a physical network function
- Managing VNF and PNF packages
- Specifying a brief description of a shared network service
- Managing virtual network functions
- Selecting the flavour of a virtual network function
- Configuring external connection points of a virtual network function
- Basic settings of a virtual network function
- Hosting the virtual network function in a data center and on a uCPE device
- Stopping or starting a virtual network function or a VDU that is part of it
- Pausing or unpausing a virtual network function or a VDU that is part of it
- Suspending or unsuspending a virtual network function or a VDU that is part of it
- Soft rebooting a virtual network function or a VDU that is part of it
- Hard rebooting of a virtual network function or a VDU that is part of it
- Redeploying a virtual network function or a VDU that is part of it
- Auto-healing a virtual network function or a VDU that is part of it
- Managing VDU snapshots
- Managing physical network functions
- Configuring a P2P service
- Configuring a P2M service
- Configuring an M2M service
- Configuring a shared network (OS 2 SHARED)
- Configuring a virtual router (OS vRouter)
- Configuring a VLAN
- Configuring a VXLAN
- Configuring a flat network
- Configuring a UNI
- Monitoring solution components
- Specifying the Zabbix server
- Specifying the Zabbix proxy server
- Configuring CPE device monitoring
- Viewing monitoring results
- Viewing problems
- Viewing the status of the solution and its components
- Viewing logs
- Viewing and deleting service requests
- Sending CPE device notifications to users
- Selecting the Docker container log verbosity
- Monitoring CPE, VNF, and PNF devices using SNMP
- Link monitoring
- Building an SD-WAN network between CPE devices
- Quality of Service (QoS)
- Transmission of traffic between CPE devices and client devices using transport services
- Traffic packet duplication
- Scenario: Directing application traffic to a transport service
- Managing Point-to-Point (P2P) transport services
- Managing Point-to-Multipoint (P2M) transport services
- Managing Multipoint-to-Multipoint (M2M) transport services
- Managing L3 VPN transport services
- Managing IP multicast transport services
- Managing transport services in an SD-WAN instance template
- Managing transport services in a CPE template
- Traffic mirroring and forwarding between CPE devices
- Appendices
- Glossary
- Control plane
- Controller
- Customer Premise Equipment (CPE)
- Data plane
- Orchestrator
- Physical Network Function (PNF)
- PNF package
- Port security
- SD-WAN Gateway
- SD-WAN instance
- Software-Defined Networking (SDN)
- Software-Defined Wide Area Network (SD-WAN)
- Tenant
- Transport strategy
- Universal CPE (uCPE)
- Virtual Deployment Unit (VDU)
- Virtual Infrastructure Manager (VIM)
- Virtual Network Function Manager (VNFM)
- VNF Package
- Contacting Technical Support
- Information about third-party code
- Trademark notices
Running the tcpdump utility
If you have previously run the tcpdump utility, a report file was generated with the captured traffic. When you run the utility again, that report file is overwritten. You can download the previous report file if you want to keep it.
The tcpdump utility puts additional load on the CPU of the CPE device.
To run the tcpdump utility:
- In the menu, go to the SD-WAN → CPE section.
A table of CPE devices is displayed.
- Click the CPE device on which you want to run the tcpdump utility.
The settings area is displayed in the lower part of the page. You can expand the settings area to fill the entire page by clicking the expand icon
. By default, the Configuration tab is selected, which displays general information about the CPE device. This tab also displays the table of Out-of-band management tasks being performed by the orchestrator.
- Select the Utilities → Tcpdump tab.
The tcpdump utility settings are displayed.
- In the Capture interface drop-down list, select the created network interface on which you want to capture traffic.
- In the Direction drop-down list, select the direction of the traffic you want to capture:
- in to capture incoming traffic.
- out to capture outgoing traffic.
- in/out to capture both incoming and outgoing traffic. Default value.
- If you want the CPE device to use the DNS server to resolve IP addresses to domain names when creating the report file with the captured traffic, select the Resolve DNS names check box. You can specify a DNS server when creating or editing a network interface. IP addresses that cannot be resolved to domain names are also reflected in the report file. This check box is cleared by default.
- If you want to use a filter to capture traffic, in the Capture expression (tcpdump filter format) field, enter the syntax of the filter. Maximum length: 1024 characters. For example, you can use the following filters:
icmp
to capture only ICMP traffic packets.host 1.2.3.4 and (port 80 or 443)
to capture only traffic packets with IPv4 address 1.2.3.4 and source or destination TCP port 80 or 443.tcp[13] & 2 != 0
to capture only TCP SYN traffic packets.
Detailed information about traffic filters can be obtained from the official tcpdump documentation.
- In the Maximum capture time (sec.) field, enter the time in seconds after which traffic capture stops. Range of values: 10 to 600. Default value:
30
. - In the Max. captured packets field, enter the number of traffic packets that you want collected before traffic capture stops. Range of values: 1 to 10,000. Default value:
1000
.Traffic capturing stops when the time specified in the Maximum capture time (sec.) field passes, or when the number of traffic packets specified in the Max. captured packets field is captured.
- Click Run.
The tcpdump utility is run on the CPE device, and a report file with the captured traffic is generated.