Kaspersky Unified Monitoring and Analysis Platform
- About Kaspersky Unified Monitoring and Analysis Platform
- Program architecture
- Installing and removing KUMA
- Program licensing
- About the End User License Agreement
- About the license
- About the License Certificate
- About the license key
- About the key file
- Adding a license key to the program web interface
- Viewing information about an added license key in the program web interface
- Removing a license key in the program web interface
- Integration with other solutions
- Integration with Kaspersky Security Center
- Configuring Kaspersky Security Center integration settings
- Adding a tenant to the list for Kaspersky Security Center integration
- Creating Kaspersky Security Center connection
- Editing Kaspersky Security Center connection
- Deleting Kaspersky Security Center connection
- Working with Kaspersky Security Center tasks
- Importing events from the Kaspersky Security Center database
- Kaspersky Endpoint Detection and Response integration
- Integration with Kaspersky CyberTrace
- Integration with Kaspersky Threat Intelligence Portal
- Integration with R-Vision Incident Response Platform
- Integration with Active Directory
- Connecting over LDAP
- Enabling and disabling LDAP integration
- Adding a tenant to the LDAP server integration list
- Creating an LDAP server connection
- Creating a copy of an LDAP server connection
- Changing an LDAP server connection
- Changing the data update frequency
- Changing the data storage period
- Starting account data update tasks
- Deleting an LDAP server connection
- Authorization with domain accounts
- Connecting over LDAP
- RuCERT integration
- Integration with Security Vision Incident Response Platform
- Kaspersky Industrial CyberSecurity for Networks integration
- Integration with Kaspersky Security Center
- KUMA resources
- KUMA services
- Analytics
- Working with tenants
- Working with incidents
- About the incidents table
- Saving and selecting incident filter configuration
- Deleting incident filter configurations
- Viewing information about an incident
- Incident creation
- Incident processing
- Changing incidents
- Automatic linking of alerts to incidents
- Categories and types of incidents
- Exporting incidents to RuCERT
- Sending incidents involving personal information leaks to RuCERT
- Working in hierarchy mode
- Working with alerts
- Working with events
- Retroscan
- Working with geographic data
- Transferring events from isolated network segments to KUMA
- Managing assets
- Asset categories
- Adding an asset category
- Configuring the table of assets
- Searching assets
- Viewing asset details
- Adding assets
- Assigning a category to an asset
- Editing the parameters of assets
- Deleting assets
- Updating third-party applications and fixing vulnerabilities on Kaspersky Security Center assets
- Moving assets to a selected administration group
- Asset audit
- Managing users
- Managing KUMA
- Contacting Technical Support
- REST API
- Creating a token
- Configuring permissions to access the API
- Authorizing API requests
- Standard error
- Operations
- Viewing a list of active lists on the correlator
- Import entries to an active list
- Searching alerts
- Closing alerts
- Searching assets
- Importing assets
- Deleting assets
- Searching events
- Viewing information about the cluster
- Resource search
- Loading resource file
- Viewing the contents of a resource file
- Importing resources
- Exporting resources
- Downloading the resource file
- Search for services
- Tenant search
- View token bearer information
- Dictionary updating in services
- Dictionary retrieval
- Appendices
- Commands for components manual starting and installing
- Integrity check of KUMA files
- Normalized event data model
- Alert data model
- Asset data model
- User account data model
- Audit event fields
- Event fields with general information
- User was successfully signed in or failed to sign in
- User login successfully changed
- User role was successfully changed
- Other data of the user was successfully changed
- User successfully logged out
- User password was successfully changed
- User was successfully created
- User access token was successfully changed
- Service was successfully created
- Service was successfully deleted
- Service was successfully reloaded
- Service was successfully restarted
- Service was successfully started
- Service was successfully paired
- Service status was changed
- Storage partition was deleted by user
- Storage partition was deleted automatically due to expiration
- Active list was successfully cleared or operation failed
- Active list item was successfully deleted or operation was unsuccessful
- Active list was successfully imported or operation failed
- Active list was exported successfully
- Resource was successfully added
- Resource was successfully deleted
- Resource was successfully updated
- Asset was successfully created
- Asset was successfully deleted
- Asset category was successfully added
- Asset category was deleted successfully
- Settings were updated successfully
- Information about third-party code
- Trademark notices
- Glossary
KUMA resources > Normalizers > Condition for forwarding data to an extra normalizer
Condition for forwarding data to an extra normalizer
Condition for forwarding data to an extra normalizer
The Add normalizer to normalization scheme window is used to specify the conditions under which the data will be sent to an extra normalizer.
Available settings:
- Fields to pass into normalizer—used to indicate event fields in case you want to send only events with specific fields to the extra normalizer.
If you leave this field blank, the full event will be sent to the extra normalizer for processing.
- Use normalizer for events with specific event field values—used to indicate event fields if you want the extra normalizer to receive only events in which specific values are assigned to certain fields. The value is specified in the Condition value field.
The data processed by these conditions can be preconverted by clicking the
button. This opens the Conversion window, in which you can use the Add conversion button to create rules for modifying the original data before it is written to the KUMA event fields.
Conversions are changes that can be applied to a value before it gets written to the event field. The conversion type is selected from a drop-down list.
Available conversions:
- lower—is used to make all characters of the value lowercase
- upper—is used to make all characters of the value uppercase
- regexp – used to convert a value using the regular expression RE2. When this conversion type is selected, the field appears where regular expression should be added.
- substring—is used to extract characters in the position range specified in the Start and End fields. These fields appear when this conversion type is selected.
- replace—is used to replace specified character sequence with the other character sequence. When this type of conversion is selected, new fields appear:
- Replace chars—in this field you can specify the character sequence that should be replaced.
- With chars—in this field you can specify the characters sequence should be used instead of replaced characters.
- trim—used to simultaneously remove the characters specified in the Chars field from the leading and end positions of the value. The field appears when this type of conversion is selected. For example, a trim conversion with the
Micromon
value applied toMicrosoft-Windows-Sysmon
results insoft-Windows-Sys
. - append is used to add the characters specified in the Constant field to the end of the event field value. The field appears when this type of conversion is selected.
- prepend—used to prepend the characters specified in the Constant field to the start of the event field value. The field appears when this type of conversion is selected.
- replace with regexp—is used to replace RE2 regular expression results with the character sequence.
- Expression—in this field you can specify the regular expression which results that should be replaced.
- With chars—in this field you can specify the characters sequence should be used instead of replaced characters.
Article ID: 221934, Last review: Mar 27, 2024